The operator has control over the workflow, and can use manual control for adapter movement and open or. Axichrom 300 to 1600 columns are controlled via axichrom master, a separate control unit with a touch screen operator interface and a motordrive. Flexfactory users manual 29164188aa typefaces automation. Preprogrammed automated methods for packing, unpacking, priming and maintenance to simplify column handling and improve uptime. Axichrom 100300 cytiva formerly ge healthcare life. In axichrom 300 and larger columns, packing is controlled by an aktaprocess system or the axichrom master, a separate unit comprising a touchscreen operator interface, a motor drive, and preprogrammed methods that support intelligent packing. Intelligent packing is performed by axichrom master, a separate unit that.
Italic type is the name of a section in this user manual. Predictable scaleup through column design and robust. Preprogrammed automated methods for packing, unpacking, priming, and maintenance to simplify column handling and improve uptime. As an etteplan consultat my project at ge healthcare included many tasks. Axichrom ge healthcare 29046543 axichrom master 3001600. User manuals, studiomaster music mixer operating guides and service manuals. Axichrom columns when packing axichrom 50 to 200 columns for use with akta systems, intelligent packing control is managed by unicorn control software. Instructions on how to install, operate and maintain axichrom 300 columns in a safe way, including instructions for axichrom master. The slurry tank can also be controlled by the axichrom master to further automate the packing procedure. Axichrom 100300 cytiva formerly ge healthcare life sciences. Omnilab is intended to acquire, display and analyze physiological data using a ni daq and personal computer. Normalized allows you to normalize one trace to fit on the graph.
Axichrom 300 to 1600 chromatography columns are controlled via axichrom master, a separate control unit with a touch screen operator interface and a motor. This integration is managed using the available profibus connection on the axichrom master. Bold type is the exact text for a term that appears on a screen. User defined allows you to enter a value for y max and min. These two positions enable filling, packing, and unpacking without adjusting the assembled column. Elinchrom us customer service instruction manualsdownloads. This manual covers the operation of both ezchrom 200, which controls the. Axichrom master and unicorn wizards guide users through key process steps to save time in method creation, setup and maintenance. This video from ge healthcare demonstrates how to pack a largescale axichrom column using the axichrom master, which guides the user through key. The lhmi display has built in support for multiple languages. User access to runs in progress as the user who submitted the run or sequence, you will have access to the stop run, extend run, or stop sequence functions. User manual the mounted zenmuse xt should look like this. Axichrom columns show excellent reproducibility independent of operator or column size.
Axichrom 300 to 1600 mm chromatography columns cytiva. The worlds first usboperated luminometer has become even more versatile. Programmable dc power supply 62000h series operating. When packing axichrom 50 to 200 columns for use with akta systems, intelligent packing control is managed by the unicorn system control software.
This manual describes the concepts of openlab cds system architecture, licensing strategy. To use this manual and omnilab software effectively, you should be familiar with the windows os. I was responsible for the production of a complete manual package for the new bioprocess column axichrom, including user. For testing products under ac line distortion conditions, clipped sinewave can be generated with 0% to 43% distortion and amplitude from 0% to 100%. Axichrom 300 to 1600 columns can be integrated into a higher level automation system, such as the deltav or siemens control systems. Axichrom master cytiva formerly ge healthcare life. It incorporates a graphictext lcd display and is designed to improve user efficiency with many features integrated to. Each zenith transfer switch is factory wired and tested.
Large axichrom columns are equipped with a twoposition media valve at the center of the bottom bed support. Overcurrent protection motor protection and control ref601. Data file 11003543 ac process chromatography aktaprocess. As soon as i was going to release it there was version 0. Manual operation of the switch must be checked before it is operated electrically.
The chroma 6500 series has builtin direct digital synthesis dds waveform generator to provide user programmable high precision waveform. The proven design has been verified during development and can be user configured to meet specific process demands. The degree of variation in plates per meter nm and asymmetries a s. For axichrom 300 to 1600 columns, intelligent packing is performed by the axichrom master, a separate unit that comprises a touchscreenoperated user interface. Note that axichrom master is not needed during chromatography operation. Always refer to the operating instructions or contact ge healthcare for detailed.
This user manual describes the operation and behavior of the 3m cleantrace luminometer. Axichrom module 29050659 and 2 axichrom master richmond. Axichrom master axichrom master is a selfcontained operator console featuring interactive guides for work procedures such as packing, unpacking and maintenance. Packing methodology axial compression packing consists of 4 main steps fig 2. It incorporates a graphictext lcd display and is designed to. Axichrom 50, 70 and 100 columns user manual axichrom 50, 70 and 100 columns unpacking instructions general specifications assembly drawings production records certificate of conformance material certificates axichrom 140 and 200 columns axichrom 140 and 200 columns user manual axichrom 140 and 200 columns unpacking instructions general. High power dc electronic load 63200 series operation. Axichrom 300 to 1600 chromatography columns are controlled via axichrom master, a separate control unit with a touch screen operator interface and a motor drive. Always refer to user manuals or contact ge healthcare for detailed information. No part of this manual may be reproduced in any form or by any means including elec. Axichrom columns let you use the full capacity of such resins. All three relays are equipped with a three level, rolebased user. Columns up to 1600 mm in diameter packed with protein a chromatography medium using axial mechanical compression johan avallin, anders nilsson, magnus asplund, niklas pettersson, tony searle, and christina jagersten. Technology solutions simplifying chromatography operations.
Do not disassemble the gimbal or camera as this will cause permanent damage. The information in this document is subject to change without notice. Luminultras photonmaster is now coupled with the photonmaster bluetooth module pbm, meaning that data can not only be generated independently from a computer, but also collected and analyzed in realtime when paired via bluetooth with our luminultra cloud mobile app. Bold type with brackets is the name of a button that you can tap or select using the cursor control button on a screen.
Description and operation of all accessories supplied. With a simple click of a mouse button, you can initiate data collection, save or retrieve data, or begin data analysis of your chromatogram. Packing capto adhere and capto mmc using verified methods. Omnilab manual 10 about this manual use the omnilab manual to learn the features, functions, and operation of omnilab. Overcurrent protection motor protection and control. A complete information package is furnished with each switch which includes. Open the bottom valve using the master manual control wizard. For information on axichrom master weight and dimensions, see appendix b column and axichrom master weights and dimensions, on page 125. Call monday friday, 8am 5pm, to talk with one of our scientific team members. Release history part number release publication date n5156023 b december 2004 user assistance perkinelmer 710 bridgeport avenue shelton, ct 064844794. Axichrom master is used to control the larger columns. Also, manual handling is kept to a minimum as the column, slurry tank, and chromatography. If you are not the user who submitted the run or sequence, you can view the run if you have instrument rights, but you cannot stop a run or sequence that has been started by another user. Y min if you have selected a user defined scale, enter a minimum value for the yaxis.
Studiomaster music mixer user manuals download manualslib. Axichrom master cytiva formerly ge healthcare life sciences. Repeated packings, by two to three different operators, of capto q in axichrom 50 at 40 cm bed height and mabselect sure packed in axichrom 1600 at 20 cm bed height. Operation manual gebrauchsanleitung manuel dutilisation handleiding english deutsch francais nederlands dlite rx 24 11.
Preprogrammed methods reduce the need for extensive packing knowhow and facilitate scaleup and tech. The interactive firmware guides the user and reduces the risk of making mistakes. For axichrom 300 to 1600 columns, intelligent packing is performed by axichrom master, a separate unit that comprises a touchscreen operated user interface, or. Intelligent packing, a feature of axichrom master, enables the automated.
Predictable scaleup through column design and robust packing. Set up the test with the axichrom column as in figure below. Data file 11003543 ac process chromatography aktaprocess aktaprocess is an automated liquid chromatography system built for process scaleup and largescale biopharmaceutical manufacturing fig 1. Axichrom master for stepbystep guidance priming groove for efficient removal of air swingoutswivel function for easy. Agilent openlab chromatography data system cds ezchrom edition. Find the user manual for your chroma instrument here. A manual operator handle is provided with the transfer switch for maintenance purposes only. The proven design has been verified during development and can be userconfigured to meet specific process demands. The question i asked myself who is going to update the manual on future releases. Elinchrom has been producing the worlds most portable studio flash, drawing from a heritage of more than 50 years of innovation. How to maintain smallscale axichrom chromatography columns.
Axichrom master controls the packing, unpacking and maintenance of large axichrom columns via a touchscreen interface. For further information refer to axichrom 300 columns user manual. Y max if you have selected a user defined scale, enter a maximum value for the yaxis. Adapter designed for maximal net area and efficient flow flat net for uniform and stable bed small area under adaptor seal for minimum dead space axichrom master for stepbystep guidance priming groove for efficient removal of air swingoutswivel function for easy maintenance resin valve with simple design to minimize dead.